Neonex Gold HRFR House Wire

PRODUCT DESIGN

APPLICABLE STANDARD

IS 694:2010

CONDUCTOR

THE CONDUCTORS DRAWN FROM 99.97 % BRIGHT ELECTROLYTIC GRADE COPPER WITH MORE THAN 100% CONDUCTIVITY ARE ANNEALED AND BUNCHED TOGETHER.

TYPE INSULATION (HRFR TYPE CPVC COMPOUND) 85°С Туре с

THE BUNCH CONDUCTORS ARE INSULATED WITH SPECIALLY FORMULATED HEAT RESISTANT FLAME RETARDANT PVC TYPE C COMPOUD WITH A HIGH INSULATION RESISTANCE VALUE. TYPE C PVC VERY HIGH INSULATION RESISTANCE COMPARE TO PVC TYPE A INSULATION THE INSULATION PROCESS IS CARRIED OUT ON MODERN HIGH SPEED EXTRUSION LINES, WHICH ENSURES HIGH ACCURACY AND CONSISTENCY IN PERFORMANCE

OPERATING TEMPERATURE RANGE

TEMP -15°C TO MAX. +85°C

COLOUR

RED, YELLOW, BLUE, BLACK, GREEN, GRAY (AND ALSO OTHER COLOUR REQUEST ON CUSTOMER)

PACKING

COILS 90m, 100m,180m, 270m BOXES, REELS

MARKING

THE CABLES ARE PRINTED WITH GENERIC MARKING NEONEX GOLD HRFR"

ADVANTAGE:

IMPROVED CURRENT CARRYING CAPACITY  
IMPROVED HV RESISTANCE  
IMPROVED LOW LEAKAGE CURRENT  
HIGH INSULATION RESISTANCE  
LOW ABSORPTION (WATER ABSORPTION)  
SAFE FOR LONG TERM USE  
VERY GOOD FLEXIBILITY  
PERFORMS BETTER WHEN EXPOSED TO THE FIRE (FIRE PROPERTING)

FEATURE

ECO FRIENDLY  
HIGH THERMAL STABILITY  
EXTRA SAFE  
20% HIGH CURRENT CARRYING CAPACITY THEN FR WIRE  
HIGH INSULATION RESISTANCE  
LONGER LIFE

APPLICATION

ISO 9001:2015, ISO 45001:2018, ISO 14001:2015, CE, RoHS

PRODUCT CERTIFICATION

IS 694:2010  IS 7098 P-1 , TUV RHEINLAND CERTIFICATE NO. R 60160877

TECHNICAL DATA

SIZE DIMENSIONS AND RATING

NOMINAL CROSS SECTIONAL AREA

NUMBER/ NOMINAL DIA OF WIRES (NOM.)

NOMINAL THICKNESS OF INSULATION

APPROX OVERALL DIA (+/-0.2 mm)

MAXIMUM DC RESISTANCE OF CONDUCTOR AT 20° C

MAX. CURRENT CARRYING CAPACITY

mm²

Number/mm

mm

mm

0/km

Amps

1

14/0.3

0.7

2.70

18.10

15

1.5

22/0.3

0.7

3.00

12.10

20

2.5

36/0.3

0.8

3.50

7.41

27

4

56/0.3

0.8

4.10

4.95

35

6

84/0.3

0.8

5.10

3.30

45

10

140/0.3

1.0

6.20

1.91

62

TEST DETAILS

FR

TEST

SPECIFICATION

SPECIFIED VALUE

CRITICAL OXYGEN INDEX

ASTM-D 2863

29% MINIMUM

TEMPERATURE INDEX

ASTM-D 2863

250 C MINIMUM

NOTE:

NOTE: FLEXIBLE CONDUCTOR AS PER IS 8130. THE NUMBER OF WIRES AND DIAMETER MENTIONED IN THE TABLE ARE APPROXIMATE AND NOMINAL, HOWEVER, THEY SHALL MEET THE REQUIREMENTS OF CONDUCTOR RESISTANCE AS PER STANDARDS. IS 8130 THE ABOVE DATA IS INDICATIVE AND MAY BE REVISED WITHOUT PRIOR INTIMATION. NEONEX CABLES WILL NOT BE LIABLE FOR ANY DAMAGES ARISING OUT OF INCORRECT APPLICATION.

×