Trusted partner for high-quality wires & cables. Contact Us Today

Follow us on :

Multicore Copper Cables

Technical Data (1.5 SQ MM COPPER CONDUCTOR UN-ARMOURED CABLES) :- CABLE CODE : 2XY

SIZE

NOMINAL INSULATION THICKNESS

MINIMUM INNER SHEATH THICKNESS

MINIMUM OUTER SHEATH THICKNESS

APPROX. OVERALL DIA OF CABLE ±2MM

APPROX. WEIGHT OF CABLE

MAX. CONDUCTOR DC RESISTANCE at 20° C (COPPER)

NOMINAL CURRENT RATING COPPER CONDUCTOR

GROUND

AIR

mm 2

mm

mm

mm

mm

Kg/Km

Ohm/Km

AMPS

2C X 1.5

0.70

0.30

1.80

10.40

140

12.10

32

27

3C X 1.5

0.70

0.30

1.80

11.00

170

12.10

25

22

4C X 1.5

0.70

0.30

1.80

11.70

200

12.10

25

22

5C X 1.5

0.70

0.30

1.80

12.90

230

12.10

24

21

Technical Data (1.5 SQ MM COPPER CONDUCTOR ARMOURED CABLES) :- CABLE CODE : 2XWY

SIZE

NOMINAL INSULATION THICKNESS

MINIMUM INNER SHEATH THICKNESS

NOMINAL ARMOUR WIRE

MINIMUM OUTER SHEATH THICKNESS

APPROX. OVERALL DIAOF CABLE ±2MM

APPROX. WEIGHT OF CABLE

MAX. CONDUCTOR DC RESISTANCE at 20° C

NOMINAL CURRENT RATING COPPER CONDUCTOR

GROUND

AIR

mm 2

mm

mm

mm

mm

mm

Kg/Km

Ohm/Km

AMPS

2C X 1.5

0.70

0.30

1.40

1.24

12.30

340

12.10

32

27

3C X 1.5

0.70

0.30

1.40

1.24

12.80

390

12.10

25

22

4C X 1.5

0.70

0.30

1.40

1.24

13.40

415

12.10

25

22

5C X 1.5

0.70

0.30

1.40

1.24

14.60

470

12.10

24

21

Technical Data (2.5 SQ MM COPPER CONDUCTOR un-ARMOURED CABLES) :- CABLE CODE 2XY

SIZE

NOMINAL INSULATION THICKNESS

MINIMUM INNER SHEATH THICKNESS

MINIMUM OUTER SHEATH THICKNESS

APPROX. DIA OF CABLE

APPROX. WEIGHT OF CABLE

MAX. CONDUCTOR DC RESISTANC 20° C (COPPER)

NOMINAL CURRENT RATING COPPER CONDUCTOR

GROUND

AIR

mm2

mm

mm

mm

mm

Kg/Km

Ohm/Km

AMPS

2C X 2.5

0 . 70

0.30

1.80

11.30

185

7.41

39

32

3C X 2.5

0.70

0.30

1.80

11.80

230

7.41

34

30

4C X 2.5

0 . 70

0.30

1.80

12.80

260

7.41

34

30

5C x 2.5

0.7

0.30

1.80

14.00

300

7.41

32

29

Technical Data (2.5 SQ MM COPPER CONDUCTOR ARMOURED CABLES) :- CABLE CODE 2XWY

SIZE

NOMINAL INSULATION THICKNESS

MINIMUM INNER SHEATH THICKNESS

NOMINAL ARMOUR WIRE

MINIMUM OUTER SHEATH THICKNESS

APPROX. OVERALL DIAOF CABLE

APPROX. WEIGHT OF CABLE

MAX. CONDUCTOR DC RESISTANCE at 20° C (COPPER)

NOMINAL CURRENT RATING COPPER CONDUCTOR

GROUND

AIR

mm2

mm

mm

mm

mm

mm

Kg/Km

Ohm/Km

AMPS

2C X 2.5

0.70

0.30

1.40

1.24

13.00

380

7.41

39

32

3C X 2.5

0.70

0.30

1.40

1.24

13.80

430

7.41

34

30

4C X 2.5

0.70

0.30

1.40

1.24

14.50

500

7.41

34

30

5C x 2.5

0.70

0.30

1.40

1.24

15.80

530

7.41

32

29

NOTE:

THE ABOVE DATA IS APPROXIMATE & SUBJECT TO MANUFACTURING TOLERANCE, 2. DELIVERY LENGTH TOLERANCE +/- 5%.

×

Hello!

Click one of our representatives below to chat on WhatsApp or send us an email to electrocabind@gmail.com

whatsapp ×