Trusted partner for high-quality wires & cables. Contact Us Today

Follow us on :

3.5 Core Aluminium / Copper

Technical Data (UN-ARMOURED CABLES) :- CABLE CODE : A2XY / 2XY         

SIZE

NOMINAL INSULATION THICKNESS

MINIMUM INNER SHEATH THICKNESS

MINIMUM OUTER SHEATH THICKNESS

APPROX. OVERALL DIAOF CABLE ±2MM

APPROX. WEIGHT OF CABLE

MAX. CONDUCTOR DC RESISTANCE at 20' C

NOMINAL CURRENT RATING ALUMINIUM CONDUCTOR

NOMINAL CURRENT RATING COPPER CONDUCTOR

A2XY

2XY

ALUMINIUM

COPPER

GROUND

AIR

GROUND

AIR

MAIN

HALF

m m2

mm

mm

mm

mm

mm

Kg/Km

Ohm/Km

AMPS

3C X 25 + 16

0.90

0.70

0.30

2.00

22.00

580

1120

1.200

0.727

96

93

121

119

3C X 35 + 16

0.90

0.70

0.30

2.00

24.00

700

1400

0.868

0.524

116

116

146

147

3C X 50 + 25

1.00

0.90

0.30

2.00

27.50

880

1880

0.641

0.387

140

140

171

178

3C X 70 + 35

1.10

0.90

0.40

2.20

31.50

1200

2620

0.443

0.268

171

175

211

225

3C X 95 + 50

1.10

1.00

0.40

2.20

35.00

1500

3490

0.320

0.193

201

217

251

278

3C X 120 + 70

1.20

1.10

0.40

2.20

39.50

1800

4320

0.253

0.153

226

250

286

318

3C X 150 + 70

1.40

1.10

0.50

2.40

43.00

2200

5230

0.206

0.124

256

285

316

364

3C X 185 + 95

1.60

1.10

0.50

2.60

47.50

2750

6580

0.164

0.0991

286

330

356

421

3C X 240 + 120

1.70

1.20

0.60

2.80

52.00

3500

8500

0.125

0.0754

327

393

411

500

3C X 300 + 150

1.80

1.40

0.60

3.00

57.00

4250

10600

0.100

0.0601

371

453

461

572

3C X 400 + 185

2.00

1.60

0.70

3.40

65.00

5450

13830

0.0778

0.0470

429

529

521

660

Technical Data (ARMOURED CABLES) :- CABLE CODE : A2XFY/ 2XFY                   

SIZE

NOMINAL INSULATION THICKNESS

MINIMUM INNER SHEATH<="" th="" style="box-sizing: border-box; margin: 0px; padding: 0px; outline: none;">

NOMINAL ARMOUR STRIP

MINIMUM OUTER SHEATH<="" th="" style="box-sizing: border-box; margin: 0px; padding: 0px; outline: none;">

APPROX. OVERALL DIAOF CABLE ±2MM

APPROX. WEIGHT OF CABLE

MAX. CONDUCTOR DC RESISTANCE at 20' C

NOMINAL CURRENT RATING ALUMINIUM CONDUCTOR

NOMINAL CURRENT RATING COPPER CONDUCTOR

A2XFY

2XFY

ALUMINIUM

COPPER

GROUND

AIR

GROUND

AIR

MAIN

HALF

mm2

mm

mm

mm

mm

mm

mm

Kg/Km

Ohm/Km

AMPS

3C X 25 + 16

0.90

0.70

0.30

4X0.8

1.40

22.00

860

1410

1.200

0.727

96

93

121

119

3C X 35 + 16

0.90

0.70

0.30

4X0.8

1.40

24.00

980

1730

0.868

0.524

116

116

146

147

3C X 50 + 25

1.00

0.90

0.30

4X0.8

1.40

27.50

1240

2300

0.641

0.387

140

140

171

178

3C X 70 + 35

1.10

0.90

0.40

4X0.8

1.56

31.50

1600

3050

0.443

0.268

171

175

211

225

3C X 95 + 50

1.10

1.00

0.40

4X0.8

1.56

35.00

1900

3950

0.320

0.193

201

217

251

278

3C X 120 + 70

1.20

1.10

0.40

4X0.8

1.72

39.50

2300

4960

0.253

0.153

226

250

286

318

3C X 150 + 70

1.40

1.10

0.50

4X0.8

1.72

43.00

2700

5880

0.206

0.124

256

285

316

364

3C X 185 + 95

1.60

1.10

0.50

4X0.8

1.88

47.50

3300

7290

0.164

0.0991

286

330

356

421

3C X 240 + 120

1.70

1.20

0.60

4X0.8

2.04

52.50

4100

9300

0.125

0.0754

327

393

411

500

3C X 300 + 150

1.80

1.40

0.60

4X0.8

2.20

57.50

4960

11400

0.100

0.0601

371

453

461

572

3C X 400 + 185

2.00

1.60

0.70

4X0.8

2.52

66.00

6200

14400

0.0778

0.0470

429

529

521

 

NOTE:

THE ABOVE DATA IS APPROXIMATE & SUBJECT TO MANUFACTURING TOLERANCE, 2. DELIVERY LENGTH TOLERANCE +/- 5%

×

Hello!

Click one of our representatives below to chat on WhatsApp or send us an email to electrocabind@gmail.com

whatsapp ×